YMC-Actus

YMC-Actus

Innovative Semi-preparative HPLC Columns

YMC-Actus Semi-preparative HPLC Columns

    Semi-preparative chromatography is the link between analytical HPLC and preparative LC. Even though the chromatographic systems used for semi-preparative LC do not reach the size of preparative LC systems, the objectives remain the same:

    • Purification and isolation of maximum sample quantity
    • Savings in time and costs.

    With YMC-Actus semi-preparative HPLC hardware time is on your side!

    • Outstanding efficiency
    • Longer lifetime
    • Higher stability towards pressure changes
    • Reliability
    • Uniform packing density

    YMC has applied its robust DAC column packing knowledge to semi-preparative column production. In combination with an innovative hardware design, YMC-Actus HPLC columns provide outstanding durability and efficiency.

    YMC-Actus series columns are semi-preparative HPLC columns that have excellent column stability and efficiency as a result of combining axial compression technology with an innovative hardware design. YMC-Actus series columns show high stability under high flow rate or steep gradient conditions which is desirable for milligram to gram scale preparative HPLC of various compounds.

    The column bed is compressed appropriately when the column inlet end is assembled with the newly designed YMC-Actus hardware. It provides increased bed density (10% higher than conventional columns), bed uniformity and prevents voids.

    Rapid pressure changes under high-speed gradient conditions may lead to column degradation and loss of column performance. With YMC-Actus a uniform packing density is provided. This results in a longer lifetime and higher resolution than conventional semi-preparative columns.

    1. Capsaicinoids in red pepper

     

    2. Glycyrrhizic acid in herbal medicine

     

    3. Pharmaceuticals

     

    4. Oligonucleotides

     

    Secured hardware stability

    A study has been performed using the 50 mm ID YMC-Actus columns for 80 hours at a constant
    maximum column pressure. An initial column performance test and after 40 hours was carried out.
    No significant changes in performance were observed after hours of continuous pressurisation.

     

     

     

     

    The inlet frit was inspected after 40 and 80 hours. On opening, neither frit distortion nor gel leakage
    was observed.

     

    Clindamycin: Scale-up Example

    Effective method development on purification
    In order to develop a successful semi-preparative method it is beneficial to proceed the following
    steps:

     

    Step 1: Developing a well optimised separation on analytical scale
    Step 2: Loading study on analytical scale
    Step 3: Scale-up to semi-preparative column dimensions
    Step 4: Quality Control

     

     

    650

     

    Title Document Type Language Phase Type Download
    YMC-Actus Semi Prep. Care and Use Care and Use Instructions E
    Chapter General Catalogue - YMC-Actus Semiprep Columns Catalogue E
    SFC Druckstabilität von YMC Actus Product Information D Please login
    SFC Pressure Stability of YMC Actus Product Information E Please login

    Please login to see the prices (if needed insert link to login page).

    Product Description Price (EUR) Stock
    AA12S05-0520WX YMC-Actus ODS-A, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    AA12S05-0530WX YMC-Actus ODS-A, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    AA12S05-1020WX YMC-Actus ODS-A, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    AA12S05-1030WX YMC-Actus ODS-A, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    AA12S05-1520WX YMC-Actus ODS-A, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    AA12S05-1530WX YMC-Actus ODS-A, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    AA12S05-2520WX YMC-Actus ODS-A, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    AA12S05-2530WX YMC-Actus ODS-A, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    AA12S05-L530WX YMC-Actus ODS-A, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    AA30S05-2520WX YMC-Actus ODS-A, semi-preparative HPLC column (20.0 mm i.d.), 30 nm, S-5 µm, 250 x 20.0 mm -
    AAG12S11-0520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 50 x 20.0 mm -
    AAG12S11-1020WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 100 x 20.0 mm -
    AAG12S11-1520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 150 x 20.0 mm -
    AAG12S11-1530WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-10 µm, 150 x 30.0 mm -
    AAG12S11-2530WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-10 µm, 250 x 30.0 mm -
    AAG12S11-L530WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-10 µm, 75 x 30.0 mm -
    AAG12S16-0520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-15 µm, 50 x 20.0 mm -
    AAG12S16-1020WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-15 µm, 100 x 20.0 mm -
    AAG12S16-1520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-15 µm, 150 x 20.0 mm -
    AAG12S16-L530WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-15 µm, 75 x 30.0 mm -
    AAG12S21-1530WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-20 µm, 150 x 30.0 mm -
    AAG30S11-1520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20 mm i.d.), 30 nm, S-10 µm, 150 x 20.0 mm -
    AAG30S11-2520WX YMC-Actus ODS-A-HG Prep, semi-preparative HPLC column (20 mm i.d.), 30 nm, S-10 µm, 250 x 20.0 mm -
    AM12S05-1520WX YMC-Actus ODS-AM, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    AM12S05-2520WX YMC-Actus ODS-AM, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    AQ12S05-0520WX YMC-Actus ODS-AQ, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    AQ12S05-0530WX YMC-Actus ODS-AQ, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    AQ12S05-1020WX YMC-Actus ODS-AQ, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    AQ12S05-1030WX YMC-Actus ODS-AQ, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    AQ12S05-1520WX YMC-Actus ODS-AQ, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    AQ12S05-1530WX YMC-Actus ODS-AQ, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    AQ12S05-2520WX YMC-Actus ODS-AQ, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    AQ12S05-2530WX YMC-Actus ODS-AQ, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    AQ12S05-L530WX YMC-Actus ODS-AQ, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    AQG12S11-1520WX YMC-Actus ODS-AQ-HG, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 150 x 20.0 mm -
    AQG12S11-1530WX YMC-Actus ODS-AQ-HG, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-10 µm, 150 x 30.0 mm -
    AQG12S11-2520WX YMC-Actus ODS-AQ-HG, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 250 x 20.0 mm -
    AQG12S11-2530WX YMC-Actus ODS-AQ-HG, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-10 µm, 250 x 30.0 mm -
    AQG20S11-2520WX YMC-Actus ODS-AQ-HG, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-10 µm, 250 x 20.0 mm -
    AS12S05-0520WX YMC-Actus Pro C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    AS12S05-0530WX YMC-Actus Pro C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    AS12S05-1020WX YMC-Actus Pro C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    AS12S05-1030WX YMC-Actus Pro C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    AS12S05-1520WX YMC-Actus Pro C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    AS12S05-1530WX YMC-Actus Pro C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    AS12S05-2520WX YMC-Actus Pro C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    AS12S05-2530WX YMC-Actus Pro C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    AS12S05-L530WX YMC-Actus Pro C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    BA99S05-0520WX YMC-Actus YMCbasic, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    BA99S05-0530WX YMC-Actus YMCbasic, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    BA99S05-1020WX YMC-Actus YMCbasic, semi-preparative HPLC column (20 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    BA99S05-1030WX YMC-Actus YMCbasic, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    BA99S05-1520WX YMC-Actus YMCbasic, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    BA99S05-1530WX YMC-Actus YMCbasic, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    BA99S05-2520WX YMC-Actus YMCbasic , semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    BA99S05-2530WX YMC-Actus YMCbasic, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    BA99S05-L530WX YMC-Actus YMCbasic, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    BA99S11-2520WX YMC-Actus YMCbasic, semi-preparative HPLC column (20.0 mm i.d.), S-10 µm, 250 x 20.0 mm -
    BS12S05-1030WX YMC-Actus Pro C4, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    BS12S05-1520WX YMC-Actus Pro C4, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    BS12S05-1530WX YMC-Actus Pro C4, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    BS12S05-2520WX YMC-Actus Pro C4, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    BU30S05-1520WX YMC-Actus Pack C4, semi-preparative HPLC column (20.0 mm i.d.), 30 nm, S-5 µm, 150 x 20.0 mm -
    BUG12S11-2520WX YMC-Actus C4-HG, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 250 x 20.0 mm -
    CN12S05-1020WX YMC-Actus CN (Cyano), semi-preparative HPLC column 20 mm i.d., 12 nm, S-5 µm, 100 x 20.0 mm -
    CN12S05-1520WX YMC-Actus CN (Cyano), semi-preparative HPLC column 20 mm i.d., 12 nm, S-5 µm, 150 x 20.0 mm -
    CN12S05-2520WX YMC-Actus Pack CN (Cyano), semi-preparative HPLC column 20 mm i.d., 12 nm, S-5 µm, 250 x 20.0 mm -
    DN12S05-2520WX YMC-Actus Diol-NP, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    DNG12S11-2530WX YMC-Actus Diol-NP, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-10 µm, 250 x 30.0 mm -
    DNG12S21-1020WX YMC-Actus Diol-NP, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-20 µm, 100 x 20.0 mm -
    DNG12S21-1520WX YMC-Actus Diol-NP, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-20 µm, 150 x 20.0 mm -
    DNG12S50-1520WX YMC-Actus Diol-NP, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-50 µm, 150 x 20.0 mm -
    HS12S05-0520WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (20 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    HS12S05-0530WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    HS12S05-1020WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (20 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    HS12S05-1030WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    HS12S05-1520WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    HS12S05-1530WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    HS12S05-2520WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    HS12S05-2530WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    HS12S05-L530WX YMC-Actus Hydrosphere C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    JH08S04-1030WX YMC-Actus J'Sphere ODS-H80, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-4 µm, 100 x 30.0 mm -
    KAN99S05-1520WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KAN99S05-1530WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KAN99S05-2520WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KAN99S05-2530WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    KAN99S11-0520WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (20.0 mm i.d.), S-10 µm, 50 x 20.0 mm -
    KAN99S11-2520WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (20.0 mm i.d.), S-10 µm, 250 x 20.0 mm -
    KAN99S11-2530WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (30.0 mm i.d.), S-10 µm, 250 x 30.0 mm -
    KAN99S21-2520WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (20.0 mm i.d.), S-20 µm, 250 x 20.0 mm -
    KAN99S21-2530WX YMC-Actus CHIRAL ART Amylose-C, semi-preparative HPLC column (30.0 mm i.d.), S-20 µm, 250 x 30.0 mm -
    KCN99S05-1520WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KCN99S05-1530WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KCN99S05-2520WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KCN99S05-2530WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    KCN99S11-2520WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (20.0 mm i.d.), S-10 µm, 250 x 20.0 mm -
    KCN99S11-2530WX YMC-Actus CHIRAL ART Cellulose-C, semi-preparative HPLC column (30.0 mm i.d.), S-10 µm, 250 x 30.0 mm -
    KSA99S05-1520WX YMC-Actus CHIRAL ART Amylose-SA, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KSA99S05-1530WX YMC-Actus CHIRAL ART Amylose-SA, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KSA99S05-2520WX YMC-Actus CHIRAL ART Amylose-SA, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KSA99S05-2530WX YMC-Actus CHIRAL ART Amylose-SA, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    KSB99S05-1520WX YMC-Actus CHIRAL ART Cellulose-SB, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KSB99S05-1530WX YMC-Actus CHIRAL ART Cellulose-SB, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KSB99S05-2520WX YMC-Actus CHIRAL ART Cellulose-SB, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KSB99S05-2530WX YMC-Actus CHIRAL ART Cellulose-SB, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    KSC99S05-1520WX YMC-Actus CHIRAL ART Cellulose-SC, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KSC99S05-1530WX YMC-Actus CHIRAL ART Cellulose-SC, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KSC99S05-2520WX YMC-Actus CHIRAL ART Cellulose-SC, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KSC99S05-2530WX YMC-Actus CHIRAL ART Cellulose-SC, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    KSJ99S05-1520WX YMC-Actus CHIRAL ART Cellulose-SJ, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 150 x 20.0 mm -
    KSJ99S05-1530WX YMC-Actus CHIRAL ART Cellulose-SJ, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 150 x 30.0 mm -
    KSJ99S05-2520WX YMC-Actus CHIRAL ART Cellulose-SJ, semi-preparative HPLC column (20.0 mm i.d.), S-5 µm, 250 x 20.0 mm -
    KSJ99S05-2530WX YMC-Actus CHIRAL ART Cellulose-SJ, semi-preparative HPLC column (30.0 mm i.d.), S-5 µm, 250 x 30.0 mm -
    NH12S05-2520WX YMC-Actus Pack NH2 (Amino), semi-preparative HPLC column 20 mm i.d., 12 nm, S-5 µm, 250 x 20.0 mm -
    OC20S05-1520WX YMC-Actus Pack C8, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-5 µm, 150 x 20.0 mm -
    OCG12S11-2520WX YMC-Actus C8-HG, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-10 µm, 250 x 20.0 mm -
    OCG12S11-2530WX YMC-Actus C8-HG (Octyl), semi-preparative HPLC column (30 mm i.d.), 12 nm, S-10 µm, 250 x 30.0 mm -
    OMG99S11-2520WX YMC-Actus Omega, semi-preparative HPLC column (20.0 mm i.d.), S-10 µm, 250 x 20.0 mm -
    OMG99S11-2530WX YMC-Actus Omega, semi-preparative HPLC column (30.0 mm i.d.), S-10 µm, 250 x 30.0 mm -
    OS12S05-0520WX YMC-Actus Pro C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    OS12S05-0530WX YMC-Actus Pro C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    OS12S05-1020WX YMC-Actus Pro C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    OS12S05-1030WX YMC-Actus Pro C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    OS12S05-1520WX YMC-Actus Pro C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    OS12S05-1530WX YMC-Actus Pro C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    OS12S05-2530WX YMC-Actus Pro C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    OS12S05-L530WX YMC-Actus Pro C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    PHG30S11-1520WX YMC-Pack Phenyl-HG, semi-preparative HPLC column (20.0 mm i.d.), 30 nm, S-10 µm, 150 x 20.0 mm -
    PV12S05-0530WX YMC-Actus PVA-Sil, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    PV12S05-1530WX YMC-Actus Pack PVA-Sil, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    PV12S05-2530WX YMC-Actus PVA-Sil, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    RS08S05-0520WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (20 mm i.d.), 8 nm, S-5 µm, 50 x 20.0 mm -
    RS08S05-0530WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (30 mm i.d.), 8 nm, S-5 µm, 50 x 30.0 mm -
    RS08S05-1020WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 100 x 20.0 mm -
    RS08S05-1030WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 100 x 30.0 mm -
    RS08S05-1520WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 150 x 20.0 mm -
    RS08S05-1530WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 150 x 30.0 mm -
    RS08S05-2520WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 250 x 20.0 mm -
    RS08S05-2530WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 250 x 30.0 mm -
    RS08S05-L530WX YMC-Actus Pro C18 RS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 75 x 30.0 mm -
    SL12S05-2520WX YMC-Actus Pack Silica, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    TA12S03-2520WX YMC-Actus Triart C18, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-3 µm, 250 x 20.0 mm -
    TA12S05-0520WX YMC-Actus Triart C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    TA12S05-0530WX YMC-Actus Triart C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    TA12S05-1020WX YMC-Actus Triart C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    TA12S05-1030WX YMC-Actus Triart C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    TA12S05-1520WX YMC-Actus Triart C18, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    TA12S05-1530WX YMC-Actus Triart C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    TA12S05-2520WX YMC-Actus Triart C18, semi-preparative HPLC column (20 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    TA12S05-2530WX YMC-Actus Triart C18, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    TA12S05-L530WX YMC-Actus Triart C18, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    TAR08S05-0520WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 50 x 20.0 mm -
    TAR08S05-0530WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 50 x 30.0 mm -
    TAR08S05-1020WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 100 x 20.0 mm -
    TAR08S05-1030WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 100 x 30.0 mm -
    TAR08S05-1520WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (20.0 mm i.d.), 8 nm, S-5 µm, 150 x 20.0 mm -
    TAR08S05-1530WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 150 x 30.0 mm -
    TAR08S05-2520WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (20 mm i.d.), 8 nm, S-5 µm, 250 x 20.0 mm -
    TAR08S05-2530WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (30 mm i.d.), 8 nm, S-5 µm, 250 x 30.0 mm -
    TAR08S05-L530WX YMC-Actus Triart C18 ExRS, semi-preparative HPLC column (30.0 mm i.d.), 8 nm, S-5 µm, 75 x 30.0 mm -
    TAS12S11-0520WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 50 x 20.0 mm -
    TAS12S11-0530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 50 x 30.0 mm -
    TAS12S11-1020WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 100 x 20.0 mm -
    TAS12S11-1030WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 100 x 30.0 mm -
    TAS12S11-1520WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 150 x 20.0 mm -
    TAS12S11-1530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 150 x 30.0 mm -
    TAS12S11-2520WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 250 x 20.0 mm -
    TAS12S11-2530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 250 x 30.0 mm -
    TAS12S11-L530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 75 x 30.0 mm -
    TAS12S16-0520WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 50 x 20.0 mm -
    TAS12S16-1020WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (20.0 mm i.d.), 12 nm, S-10 µm, 50 x 20.0 mm -
    TAS12S16-2520WX YMC-Actus Triart C18-S, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-15 µm, 250 x 20.0 mm -
    TAS12S16-2530WX YMC-Actus Triart C18-S, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-15 µm, 250 x 30.0 mm -
    TAS12S16-L530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-10 µm, 75 x 30.0 mm -
    TAS12S21-1030WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-20 µm, 100 x 30.0 mm -
    TAS12S21-2530WX YMC-Actus Triart Prep C18-S, semi-preparative HPLC-column (30.0 mm i.d.), 12 nm, S-20 µm, 250 x 30.0 mm -
    TDH12S05-0520WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    TDH12S05-0530WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    TDH12S05-1020WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    TDH12S05-1030WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    TDH12S05-1520WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    TDH12S05-2520WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    TDH12S05-2530WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    TDH12S05-L530WX YMC-Actus Triart Diol-HILIC, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    TO12S05-0520WX YMC-Actus Triart C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 50 x 20.0 mm -
    TO12S05-0530WX YMC-Actus Triart C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 50 x 30.0 mm -
    TO12S05-1020WX YMC-Actus Triart C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 100 x 20.0 mm -
    TO12S05-1030WX YMC-Actus Triart C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    TO12S05-1520WX YMC-Actus Triart C8, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    TO12S05-1530WX YMC-Actus Triart C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 150 x 30.0 mm -
    TO12S05-2520WX YMC-Actus Triart C8, semi-preparative HPLC column (20 mm i.d.), 12 nm, S-5 µm, 250 x 20.0 mm -
    TO12S05-2530WX YMC-Actus Triart C8, semi-preparative HPLC column (30 mm i.d.), 12 nm, S-5 µm, 250 x 30.0 mm -
    TO12S05-L530WX YMC-Actus Triart C8, semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 75 x 30.0 mm -
    TOS20S11-0520WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-10 µm, 50 x 20.0 mm -
    TOS20S11-1020WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-10 µm, 100 x 20.0 mm -
    TOS20S11-1520WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-10 µm, 150 x 20.0 mm -
    TOS20S11-1530WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (30.0 mm i.d.), 20 nm, S-10 µm, 150 x 30.0 mm -
    TOS20S11-2520WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-10 µm, 250 x 20.0 mm -
    TOS20S11-2530WX YMC-Actus Triart C8-S, semi-preparative HPLC column (30 mm i.d.), 20 nm, S-10 µm, 250 x 30.0 mm -
    TOS20S21-1020WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-20 µm, 100 x 20.0 mm -
    TOS20S21-1520WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (20.0 mm i.d.), 20 nm, S-20 µm, 150 x 20.0 mm -
    TOS20S21-1530WX YMC-Actus Triart C8-S Prep, semi-preparative HPLC column (30.0 mm i.d.), 20 nm, S-20 µm, 150 x 30.0 mm -
    TPF12S05-1030WX YMC-Actus Triart PFP,semi-preparative HPLC column (30.0 mm i.d.), 12 nm, S-5 µm, 100 x 30.0 mm -
    TPF12S05-1520WX YMC-Actus Triart PFP, semi-preparative HPLC column (20.0 mm i.d.), 12 nm, S-5 µm, 150 x 20.0 mm -
    • 2-3 days
    • 1-2 weeks
    • 3-4 weeks

    Related Categories

    Contact

    • Dr. Daniel Eßer
    • Product Manager
    • Analytical Chromatography
    • ph. +49 (0)2064 427-280